<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-30 08-00-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 41 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 67 kHz 10079 1,4585
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,2 dBr 4,42 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 13 kHz % above 76 kHz: 1,4585 Acquired: 2026/04/30 7.59.14 Total samples: 10079 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,3 dBr MIN: 3,2 dBr AVE: 4,42 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2026/04/30 7.59.13) 07.46 07.48 07.50 07.52 07.54 07.56 07.58 0 2 4 6 Pm [dBr]